passlisted in Coinbase#83 by calls of 844 on this host
0.005 USDC
per call, as the listing declares it on eip155:
- Validation state
- pass
- Uptime, 7 / 30 / 90 days
- 100% / 100% / 100%
- Calls, trailing 30 days
- 1
- Unique payers, trailing 30 days
- 1
- Last called
- 2026-09-28 15:13 UTC
- First observed by TOLLderived
- 2026-09-28
- Pricederived
- 0.005 USDC
- Networks
- 1
How big is this endpoint among the ones like it?
No trace is drawn of this endpoint’s own volume. Its counters have changed 2 times across 12 observations, and 3 changes are the fewest this site will draw a trace through, because two points and a guess are not a series. Every observation is in the JSON.
api.magentlab.com lists 844 endpoints; calc hep is tied 83rd by calls with 761 others.
Its declared inputs are a JSON body with the field items.
calc hep returns json; the example shows path, count and items.
In the trailing 30 days: one call, one payer.
calc hep was last called 4 days before the snapshot.
On Base, calc hep asks 0.005 USDC per call.
At api.magentlab.com, calc hep takes POST requests, is listed in the Coinbase registry, and falls under the "other" category by TOLL's rules.
calc hep answered the sweep of 2026-10-02 with a valid 402, as at every sweep since 2026-09-28.
Closest in price to calc hep within the "other" category: ping at www.api-xpay.com and aviation airport status at api.x402node.dev.
calc hep is priced above 43% of comparable listings in the "other" category.
The wallet paid by calc hep is the payee of 844 endpoints on one host.
Seller tags: hep, hit, heparin and thrombocytopenia.
The price of calc hep is declared by 737 other listings in the "other" category too.
the payment options, as of 2026-10-02 12:31 UTC · method · pinnable
| registry | network | asset | amount | scheme | pay to |
|---|---|---|---|---|---|
| Coinbase | eip155: | USDC | 0.005 USDC | exact | 0x836Be2…c19Ee2 |
the checks, as of 2026-10-02 15:34 UTC · method · pinnableendpoint answered HTTP 402
No named check failed.
Every sweep that observed this endpoint, newest first.
| observed, UTC | state | failed checks | sweep |
|---|---|---|---|
| 2026-10-02 15:34 UTC | pass | 0 | daily-2026-10-02 |
| 2026-10-01 08:23 UTC | pass | 0 | daily-2026-10-01 |
| 2026-09-30 07:45 UTC | pass | 0 | daily-2026-09-30 |
| 2026-09-29 19:58 UTC | pass | 0 | daily-2026-09-29 |
| 2026-09-28 17:02 UTC | pass | 0 | daily-2026-09-28 |
| 2026-09-28 16:45 UTC | pass | 0 | new-after-daily-2026-09-28 |
Presence in a registry, not liveness of the service (method). Newest first.
- listed in Coinbase
From the registry record, not validated by TOLL.the declared schema, as of 2026-09-28 15:13 UTC · method · live
The input and output block
{
"input": {
"body": {
"items": [
{
"nadir": "gt_20",
"timing": "typical_5_10",
"cpb_96h": false,
"bleeding": false,
"magnitude": "gt_50",
"overt_dic": false,
"thrombosis": "typical_new_ge_4d",
"skin_necrosis": false,
"no_other_cause": true,
"severe_infection": false,
"systemic_reaction": false,
"intra_arterial_device": false,
"chronic_thrombocytopenia": false,
"new_drug_thrombocytopenia": false
},
{
"nadir": "gt_20",
"timing": "typical_5_10",
"cpb_96h": false,
"bleeding": false,
"magnitude": "gt_50",
"overt_dic": false,
"thrombosis": "typical_new_ge_4d",
"skin_necrosis": false,
"no_other_cause": true,
"severe_infection": false,
"systemic_reaction": false,
"intra_arterial_device": false,
"chronic_thrombocytopenia": false,
"new_drug_thrombocytopenia": false
}
]
},
"type": "http",
"method": "POST"
},
"output": {
"type": "json",
"example": {
"path": "/api/calc/hep",
"count": 2,
"items": [
{
"score": 14,
"formula": "hep",
"citation": {
"id": "cuker-2010",
"doi": "10.1111/j.1538-7836.2010.04059.x",
"pmid": "20854372",
"title": "The HIT Expert Probability (HEP) Score: a novel pre-test probability model for heparin-induced thrombocytopenia based on broad expert opinion",
"source": "J Thromb Haemost. 2010;8(12):2642-2650",
"authors": "Cuker A, Arepally G, Crowther MA, Rice L, Datko F, Hook K, Propert KJ, Kuter DJ, Ortel TL, Konkle BA, Cines DB"
},
"max_score": 19,
"components": [
{
"value": "gt_50",
"factor": "magnitude",
"points": 3,
"present": true
},
{
"value": "typical_5_10",
"factor": "timing",
"points": 3,
"present": true
},
{
"value": "gt_20",
"factor": "nadir",
"points": 2,
"present": true
},
{
"value": "typical_new_ge_4d",
"factor": "thrombosis",
"points": 3,
"present": true
},
{
"factor": "skin_necrosis",
"points": 0,
"present": false
},
{
"factor": "systemic_reaction",
"points": 0,
"present": false
},
{
"factor": "bleeding",
"points": 0,
"present": false
},
{
"factor": "chronic_thrombocytopenia",
"points": 0,
"present": false
},
{
"factor": "new_drug_thrombocytopenia",
"points": 0,
"present": false
},
{
"factor": "severe_infection",
"points": 0,
"present": false
},
{
"factor": "overt_dic",
"points": 0,
"present": false
},
{
"factor": "intra_arterial_device",
"points": 0,
"present": false
},
{
"factor": "cpb_96h",
"points": 0,
"present": false
},
{
"factor": "no_other_cause",
"points": 3,
"present": true
}
],
"disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
"score_ge_2": true,
"score_ge_5": true,
"formula_expression": "HEP = magnitude (lt_30 -1, 30_to_50 1, gt_50 3) + timing (typical_lt_4 -2, typical_day_4 2, typical_5_10 3, typical_11_14 2, typical_gt_14 -1; rapid_lt_48h 2, rapid_gt_48h -1) + nadir (le_20 -2, gt_20 2) + thrombosis select at most one (none 0; typical_new_ge_4d 3, typical_progression 2; rapid_new 3, rapid_progression 2) + skin_necrosis 3 + systemic_reaction 2 + bleeding -1 + other causes select all (chronic_thrombocytopenia -1, new_drug_thrombocytopenia -2, severe_infection -2, overt_dic -2, intra_arterial_device -2, cpb_96h -1, no_other_cause 3 mutually exclusive with other causes); Cuker 2010; range -16 to 19; cutoff 2 was 100% sensitive / 60% specific vs expert panel; cutoff 5 was 86% sensitive / 88% specific"
},
{
"score": 14,
"formula": "hep",
"citation": {
"id": "cuker-2010",
"doi": "10.1111/j.1538-7836.2010.04059.x",
"pmid": "20854372",
"title": "The HIT Expert Probability (HEP) Score: a novel pre-test probability model for heparin-induced thrombocytopenia based on broad expert opinion",
"source": "J Thromb Haemost. 2010;8(12):2642-2650",
"authors": "Cuker A, Arepally G, Crowther MA, Rice L, Datko F, Hook K, Propert KJ, Kuter DJ, Ortel TL, Konkle BA, Cines DB"
},
"max_score": 19,
"components": [
{
"value": "gt_50",
"factor": "magnitude",
"points": 3,
"present": true
},
{
"value": "typical_5_10",
"factor": "timing",
"points": 3,
"present": true
},
{
"value": "gt_20",
"factor": "nadir",
"points": 2,
"present": true
},
{
"value": "typical_new_ge_4d",
"factor": "thrombosis",
"points": 3,
"present": true
},
{
"factor": "skin_necrosis",
"points": 0,
"present": false
},
{
"factor": "systemic_reaction",
"points": 0,
"present": false
},
{
"factor": "bleeding",
"points": 0,
"present": false
},
{
"factor": "chronic_thrombocytopenia",
"points": 0,
"present": false
},
{
"factor": "new_drug_thrombocytopenia",
"points": 0,
"present": false
},
{
"factor": "severe_infection",
"points": 0,
"present": false
},
{
"factor": "overt_dic",
"points": 0,
"present": false
},
{
"factor": "intra_arterial_device",
"points": 0,
"present": false
},
{
"factor": "cpb_96h",
"points": 0,
"present": false
},
{
"factor": "no_other_cause",
"points": 3,
"present": true
}
],
"disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
"score_ge_2": true,
"score_ge_5": true,
"formula_expression": "HEP = magnitude (lt_30 -1, 30_to_50 1, gt_50 3) + timing (typical_lt_4 -2, typical_day_4 2, typical_5_10 3, typical_11_14 2, typical_gt_14 -1; rapid_lt_48h 2, rapid_gt_48h -1) + nadir (le_20 -2, gt_20 2) + thrombosis select at most one (none 0; typical_new_ge_4d 3, typical_progression 2; rapid_new 3, rapid_progression 2) + skin_necrosis 3 + systemic_reaction 2 + bleeding -1 + other causes select all (chronic_thrombocytopenia -1, new_drug_thrombocytopenia -2, severe_infection -2, overt_dic -2, intra_arterial_device -2, cpb_96h -1, no_other_cause 3 mutually exclusive with other causes); Cuker 2010; range -16 to 19; cutoff 2 was 100% sensitive / 60% specific vs expert panel; cutoff 5 was 86% sensitive / 88% specific"
}
]
}
}
}Cite this page
The pinned URL below renders this page from the snapshot of 2026-10-02 12:31 UTC and does not change; the live page does, every six hours. Data reuse is under CC BY 4.0 (terms).
Plain text
TOLL, "calc hep on api.magentlab.com", snapshot of 2026-10-02 12:31 UTC. https://tollindex.com/e/api-magentlab-com-api-calc-hep-8a8596/at/2026-10-02T12-31Z. Accessed [access date].
BibTeX
@misc{toll-e-api-magentlab-com-api-calc-hep-8a8596-2026-10-02T12-31Z,
author = {TOLL},
title = {calc hep on api.magentlab.com},
howpublished = {\url{https://tollindex.com/e/api-magentlab-com-api-calc-hep-8a8596/at/2026-10-02T12-31Z}},
year = {2026},
month = {10},
note = {Pinned view of the snapshot of 2026-10-02 12:31 UTC. Accessed [access date].}
}None yet. Anything submitted through the form below is published here with its outcome.