{"api":"v1","generated_at":"2026-09-16T02:02:30.754Z","licence":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/","attribution":"TOLL, with a link to the page cited"},"page":"https://tollindex.com/e/solar-halowerk-com-inverter-losses-01cc6c","pinned_page":"https://tollindex.com/e/solar-halowerk-com-inverter-losses-01cc6c/at/2026-09-15T21-20Z","pinned":false,"method":"https://tollindex.com/ledger/method","snapshot_at":"2026-09-15T21:20:12.737Z","snapshot_stamp":"2026-09-15T21-20Z","endpoint":{"slug":"solar-halowerk-com-inverter-losses-01cc6c","canonical_url":"https://solar.halowerk.com/inverter-losses","resource":"https://solar.halowerk.com/inverter-losses","http_method":"POST","type":"http","x402_version":2,"registries":[],"primary_registry":"cdp","curated_by_coinbase":false,"description":"Cable loss uses the DC resistance of the two-way run at twenty degrees Celsius; warm cable in a hot compartment carries roughly four percent more resistance per ten kelvin, which is not applied. Inverter loss follows a three-part model of idle draw, a proportional share and a quadratic share, fitted so that the stated peak efficiency is met near half of the rated power.","service_name":null,"declared_category":null,"declared_tags":[],"route_template":null,"registry_updated":"2026-08-14T07:29:55.064Z"},"derived":{"note":"fields no registry supplies; TOLL derives them and marks them derived on the page","title":"inverter losses","category":"inference","first_observed_by_toll":"2026-09-10T19:08:24.178Z","last_observed_by_toll":"2026-09-13T04:45:15.765Z","observation_began":"2026-09-10"},"presence":{"listed_now":false,"first_absent_at":"2026-09-13T11:49:46.237Z","delisting_confirmed_at":"2026-09-13T16:15:14.706Z","events":[{"registry":"cdp","at":"2026-09-10T19:08:24.178Z","event":"listed"},{"registry":"cdp","at":"2026-09-13T11:49:46.237Z","event":"delisted"},{"registry":"cdp","at":"2026-09-13T16:15:14.706Z","event":"delisting_confirmed"}]},"accepts":[{"registry":"cdp","ordinal":0,"network":"eip155:8453","asset":"0x833589fcd6edb6e08f4c7c32d4f71b54bda02913","asset_name":"USD Coin","symbol":"USDC","decimals":6,"amount_display":"0.002 USDC","amount_units":0.002,"decimals_known":true,"pay_to":"0x2880EdfFF13100677Bf97A3CBdF3Bc34771C4E5E","scheme":"exact"}],"counters":{"observed_at":"2026-09-13T04:45:15.766Z","calls_30d":1,"unique_payers_30d":1,"last_called_at":"2026-08-14T07:29:54.585Z"},"validation":{"latest":{"observed_at":"2026-09-13T03:48:42.156Z","state":"pass","failed_checks":["bazaar.info.output"],"endpoint_http_status":402,"run_id":"daily-2026-09-13"},"uptime":[{"days":7,"observed":3,"passed":3,"ratio":1},{"days":30,"observed":3,"passed":3,"ratio":1},{"days":90,"observed":3,"passed":3,"ratio":1}],"history_90d":[{"observed_at":"2026-09-13T03:48:42.156Z","state":"pass","failed_checks":["bazaar.info.output"],"run_id":"daily-2026-09-13","state_changed":false},{"observed_at":"2026-09-12T04:14:12.416Z","state":"pass","failed_checks":["bazaar.info.output"],"run_id":"daily-2026-09-12","state_changed":false},{"observed_at":"2026-09-11T09:27:08.434Z","state":"pass","failed_checks":["bazaar.info.output"],"run_id":"daily-2026-09-11","state_changed":true}]},"seller":{"wallet":"0x2880EdfFF13100677Bf97A3CBdF3Bc34771C4E5E","page":"https://tollindex.com/seller/0x2880EdfFF13100677Bf97A3CBdF3Bc34771C4E5E","endpoints":1553,"hosts":67},"reports":0,"registry_record":{"cdp":[{"type":"http","accepts":[{"asset":"0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913","extra":{"name":"USD Coin","asset":"USDC","version":"2","eip712Domain":{"name":"USD Coin","chainId":8453,"version":"2","verifyingContract":"0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913"},"network_name":"Base Mainnet","assetTransferMethod":"eip3009"},"payTo":"0x2880EdfFF13100677Bf97A3CBdF3Bc34771C4E5E","amount":"2000","scheme":"exact","network":"eip155:8453","currency":"0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913","recipient":"0x2880EdfFF13100677Bf97A3CBdF3Bc34771C4E5E","maxTimeoutSeconds":300}],"quality":{"lastCalledAt":"2026-08-14T07:29:54.585Z","l30DaysTotalCalls":1,"l30DaysUniquePayers":1},"resource":"https://solar.halowerk.com/inverter-losses","extensions":{"bazaar":{"info":{"input":{"body":{"load_w":1,"battery_voltage_v":6},"type":"http","method":"POST","bodyType":"json"}},"schema":{"type":"object","$schema":"https://json-schema.org/draft/2020-12/schema","required":["input"],"properties":{"input":{"type":"object","required":["type","method","bodyType","body"],"properties":{"body":{"type":"object","required":["load_w","battery_voltage_v"],"properties":{"cable":{"type":"object","required":["length_m","cross_section_mm2"],"properties":{"length_m":{"type":"number","maximum":200,"minimum":0.1,"description":"One-way run; the calculation doubles it."},"material":{"enum":["copper","aluminium"],"type":"string","default":"copper"},"cross_section_mm2":{"type":"number","maximum":500,"minimum":0.5}},"additionalProperties":false},"load_w":{"type":"number","maximum":100000,"minimum":1,"description":"AC power drawn at the output."},"inverter":{"type":"object","properties":{"idle_w":{"type":"number","default":15,"maximum":500,"minimum":0},"rated_w":{"type":"number","default":1200,"maximum":100000,"minimum":50},"peak_efficiency":{"type":"number","default":0.93,"maximum":0.99,"minimum":0.5},"efficiency_at_load":{"type":"number","maximum":0.99,"minimum":0.3,"description":"Measured efficiency at this exact load, overrides the model."}},"additionalProperties":false},"battery_voltage_v":{"type":"number","maximum":1000,"minimum":6},"max_voltage_drop_percent":{"type":"number","default":3,"maximum":10,"minimum":0.5}},"additionalProperties":false},"type":{"type":"string","const":"http"},"method":{"enum":["POST","PUT","PATCH"],"type":"string"},"bodyType":{"enum":["json","form-data","text"],"type":"string"}},"additionalProperties":false}}}}},"description":"Cable loss uses the DC resistance of the two-way run at twenty degrees Celsius; warm cable in a hot compartment carries roughly four percent more resistance per ten kelvin, which is not applied. Inverter loss follows a three-part model of idle draw, a proportional share and a quadratic share, fitted so that the stated peak efficiency is met near half of the rated power.","lastUpdated":"2026-08-14T07:29:55.064Z","x402Version":2}]}}