{"api":"v1","generated_at":"2026-09-15T19:53:39.653Z","licence":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/","attribution":"TOLL, with a link to the page cited"},"page":"https://tollindex.com/e/solar-halowerk-com-inverter-load-check-fceaae","pinned_page":"https://tollindex.com/e/solar-halowerk-com-inverter-load-check-fceaae/at/2026-09-15T16-57Z","pinned":false,"method":"https://tollindex.com/ledger/method","snapshot_at":"2026-09-15T16:57:44.360Z","snapshot_stamp":"2026-09-15T16-57Z","endpoint":{"slug":"solar-halowerk-com-inverter-load-check-fceaae","canonical_url":"https://solar.halowerk.com/inverter-load-check","resource":"https://solar.halowerk.com/inverter-load-check","http_method":"POST","type":"http","x402_version":2,"registries":["cdp"],"primary_registry":"cdp","curated_by_coinbase":false,"description":"Continuous load is the sum of the running watts of all appliances marked as simultaneous. The surge check adds the largest single starting surge on top of the continuous load, which is the case that trips an inverter; simultaneous starts of two motors are reported separately as a second figure. Starting factors and power factors are design rules of thumb per appliance class and are stated in the response, they are not device data.","service_name":null,"declared_category":null,"declared_tags":[],"route_template":null,"registry_updated":"2026-08-17T11:25:52.731Z"},"derived":{"note":"fields no registry supplies; TOLL derives them and marks them derived on the page","title":"inverter load check","category":"other","first_observed_by_toll":"2026-09-10T19:08:24.178Z","last_observed_by_toll":"2026-09-15T16:57:44.360Z","observation_began":"2026-09-10"},"presence":{"listed_now":true,"first_absent_at":null,"delisting_confirmed_at":null,"events":[{"registry":"cdp","at":"2026-09-10T19:08:24.178Z","event":"listed"}]},"accepts":[{"registry":"cdp","ordinal":0,"network":"eip155:8453","asset":"0x833589fcd6edb6e08f4c7c32d4f71b54bda02913","asset_name":"USD Coin","symbol":"USDC","decimals":6,"amount_display":"0.002 USDC","amount_units":0.002,"decimals_known":true,"pay_to":"0x2880EdfFF13100677Bf97A3CBdF3Bc34771C4E5E","scheme":"exact"}],"counters":{"observed_at":"2026-09-15T16:57:44.360Z","calls_30d":3,"unique_payers_30d":1,"last_called_at":"2026-08-17T11:25:52.238Z"},"validation":{"latest":{"observed_at":"2026-09-15T07:08:17.933Z","state":"pass","failed_checks":["bazaar.info.output"],"endpoint_http_status":402,"run_id":"daily-2026-09-15"},"uptime":[{"days":7,"observed":5,"passed":5,"ratio":1},{"days":30,"observed":5,"passed":5,"ratio":1},{"days":90,"observed":5,"passed":5,"ratio":1}],"history_90d":[{"observed_at":"2026-09-15T07:08:17.933Z","state":"pass","failed_checks":["bazaar.info.output"],"run_id":"daily-2026-09-15","state_changed":false},{"observed_at":"2026-09-14T06:34:14.544Z","state":"pass","failed_checks":["bazaar.info.output"],"run_id":"daily-2026-09-14","state_changed":false},{"observed_at":"2026-09-13T06:23:16.679Z","state":"pass","failed_checks":["bazaar.info.output"],"run_id":"daily-2026-09-13","state_changed":false},{"observed_at":"2026-09-12T13:56:36.734Z","state":"pass","failed_checks":["bazaar.info.output"],"run_id":"daily-2026-09-12","state_changed":false},{"observed_at":"2026-09-11T14:53:29.940Z","state":"pass","failed_checks":["bazaar.info.output"],"run_id":"daily-2026-09-11","state_changed":true}]},"seller":{"wallet":"0x2880EdfFF13100677Bf97A3CBdF3Bc34771C4E5E","page":"https://tollindex.com/seller/0x2880EdfFF13100677Bf97A3CBdF3Bc34771C4E5E","endpoints":1553,"hosts":67},"reports":0,"registry_record":{"cdp":[{"type":"http","accepts":[{"asset":"0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913","extra":{"name":"USD Coin","asset":"USDC","version":"2","eip712Domain":{"name":"USD Coin","chainId":8453,"version":"2","verifyingContract":"0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913"},"network_name":"Base Mainnet","assetTransferMethod":"eip3009"},"payTo":"0x2880EdfFF13100677Bf97A3CBdF3Bc34771C4E5E","amount":"2000","scheme":"exact","network":"eip155:8453","currency":"0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913","recipient":"0x2880EdfFF13100677Bf97A3CBdF3Bc34771C4E5E","maxTimeoutSeconds":300}],"quality":{"lastCalledAt":"2026-08-17T11:25:52.238Z","l30DaysTotalCalls":3,"l30DaysUniquePayers":1},"resource":"https://solar.halowerk.com/inverter-load-check","extensions":{"bazaar":{"info":{"input":{"body":{"loads":[{"name":"Beispiel","watts":0.1,"quantity":1}],"inverter":{"surge_w":50,"efficiency":0.9,"continuous_w":50}},"type":"http","method":"POST","bodyType":"json"}},"schema":{"type":"object","$schema":"https://json-schema.org/draft/2020-12/schema","required":["input"],"properties":{"input":{"type":"object","required":["type","method","bodyType","body"],"properties":{"body":{"type":"object","required":["inverter","loads"],"properties":{"loads":{"type":"array","items":{"type":"object","required":["name","watts"],"properties":{"name":{"type":"string"},"type":{"type":"string","description":"Appliance class: resistive, electronics, led, motor, pump, compressor, induction."},"watts":{"type":"number","maximum":50000,"minimum":0.1},"quantity":{"type":"integer","default":1,"maximum":200,"minimum":1},"power_factor":{"type":"number","maximum":1,"minimum":0.3},"simultaneous":{"type":"boolean","default":true,"description":"False if the appliance never runs together with the others."},"surge_factor":{"type":"number","maximum":12,"minimum":1}},"additionalProperties":false},"maxItems":60,"minItems":1},"inverter":{"type":"object","required":["continuous_w"],"properties":{"idle_w":{"type":"number","default":15,"maximum":500,"minimum":0},"surge_w":{"type":"number","maximum":400000,"minimum":50,"description":"Peak rating. Defaults to twice the continuous rating."},"efficiency":{"type":"number","default":0.9,"maximum":1,"minimum":0.5},"continuous_w":{"type":"number","maximum":100000,"minimum":50}},"additionalProperties":false},"battery_voltage_v":{"type":"number","maximum":1000,"minimum":6,"description":"For the DC current figure. Without it that field stays null."}},"additionalProperties":false},"type":{"type":"string","const":"http"},"method":{"enum":["POST","PUT","PATCH"],"type":"string"},"bodyType":{"enum":["json","form-data","text"],"type":"string"}},"additionalProperties":false}}}}},"description":"Continuous load is the sum of the running watts of all appliances marked as simultaneous. The surge check adds the largest single starting surge on top of the continuous load, which is the case that trips an inverter; simultaneous starts of two motors are reported separately as a second figure. Starting factors and power factors are design rules of thumb per appliance class and are stated in the response, they are not device data.","lastUpdated":"2026-08-17T11:25:52.731Z","x402Version":2}]}}