{"api":"v1","generated_at":"2026-10-01T04:28:16.110Z","licence":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/","attribution":"TOLL, with a link to the page cited"},"page":"https://tollindex.com/e/api-magentlab-com-api-calc-ohfrs-eef990","pinned_page":"https://tollindex.com/e/api-magentlab-com-api-calc-ohfrs-eef990/at/2026-09-30T22-14Z","pinned":false,"method":"https://tollindex.com/ledger/method","snapshot_at":"2026-09-30T22:14:11.940Z","snapshot_stamp":"2026-09-30T22-14Z","endpoint":{"slug":"api-magentlab-com-api-calc-ohfrs-eef990","canonical_url":"https://api.magentlab.com/api/calc/ohfrs","resource":"https://api.magentlab.com/api/calc/ohfrs","http_method":"POST","type":"http","x402_version":2,"registries":["cdp"],"primary_registry":"cdp","curated_by_coinbase":false,"description":"Ottawa Heart Failure Risk Scale (OHFRS; Stiell 2013 derivation). Ten caller-assigned flags (stroke/TIA 1, intubation 2, arrival HR >=110 2, arrival SaO2 <90% 1, walk-test HR >=110 or unable 1, new ischemic ECG 2, urea >=12 mmol/L 1, CO2 >=35 mmol/L 2, troponin at MI level 2, NT-proBNP >=5000 ng/L 1); integer points, max 15. Derivation SAE risk 2.8% to 89.0%. Not a medical device, not a disposition or discharge order, not EHMRG. magent does not walk the patient or read the ECG.","service_name":"magent","declared_category":null,"declared_tags":["ohfrs","heart-failure","emergency","stiell","calculator"],"route_template":null,"registry_updated":"2026-09-28T14:47:54.478Z"},"derived":{"note":"fields no registry supplies; TOLL derives them and marks them derived on the page","title":"calc ohfrs","category":"other","first_observed_by_toll":"2026-09-28T13:51:25.436Z","last_observed_by_toll":"2026-09-30T22:14:11.940Z","observation_began":"2026-09-10"},"presence":{"listed_now":true,"first_absent_at":null,"delisting_confirmed_at":null,"events":[{"registry":"cdp","at":"2026-09-28T13:51:25.437Z","event":"listed"}]},"accepts":[{"registry":"cdp","ordinal":0,"network":"eip155:8453","asset":"0x833589fcd6edb6e08f4c7c32d4f71b54bda02913","asset_name":"USD Coin","symbol":"USDC","decimals":6,"amount_display":"0.005 USDC","amount_units":0.005,"decimals_known":true,"pay_to":"0x836Be278f1739fB4308091cD1852F7971Bc19Ee2","scheme":"exact"}],"counters":{"observed_at":"2026-09-30T22:14:11.940Z","calls_30d":1,"unique_payers_30d":1,"last_called_at":"2026-09-28T14:47:54.336Z"},"validation":{"latest":{"observed_at":"2026-09-30T09:23:07.533Z","state":"pass","failed_checks":[],"endpoint_http_status":402,"run_id":"daily-2026-09-30"},"uptime":[{"days":7,"observed":3,"passed":3,"ratio":1},{"days":30,"observed":3,"passed":3,"ratio":1},{"days":90,"observed":3,"passed":3,"ratio":1}],"history_90d":[{"observed_at":"2026-09-30T09:23:07.533Z","state":"pass","failed_checks":[],"run_id":"daily-2026-09-30","state_changed":false},{"observed_at":"2026-09-29T21:28:15.785Z","state":"pass","failed_checks":[],"run_id":"daily-2026-09-29","state_changed":false},{"observed_at":"2026-09-28T16:50:49.392Z","state":"pass","failed_checks":[],"run_id":"new-after-daily-2026-09-28","state_changed":true}]},"seller":{"wallet":"0x836Be278f1739fB4308091cD1852F7971Bc19Ee2","page":"https://tollindex.com/seller/0x836Be278f1739fB4308091cD1852F7971Bc19Ee2","endpoints":844,"hosts":1},"reports":0,"registry_record":{"cdp":[{"tags":["ohfrs","heart-failure","emergency","stiell","calculator"],"type":"http","accepts":[{"asset":"0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913","extra":{"name":"USD Coin","version":"2","paymentFlow":"upfront","resourceUrl":"https://api.magentlab.com/api/calc/ohfrs","assetTransferMethod":"eip3009"},"payTo":"0x836Be278f1739fB4308091cD1852F7971Bc19Ee2","amount":"5000","scheme":"exact","network":"eip155:8453","maxTimeoutSeconds":600}],"quality":{"lastCalledAt":"2026-09-28T14:47:54.336Z","l30DaysTotalCalls":1,"l30DaysUniquePayers":1},"resource":"https://api.magentlab.com/api/calc/ohfrs","extensions":{"bazaar":{"info":{"input":{"body":{"items":[{"co2_ge_35_mmol_l":false,"new_ischemic_ecg":false,"ntprobnp_ge_5000":false,"hr_arrival_ge_110":false,"troponin_mi_level":false,"urea_ge_12_mmol_l":false,"sao2_lt_90_arrival":false,"history_stroke_or_tia":false,"walk_test_hr_ge_110_or_unable":false,"intubation_respiratory_distress":false},{"co2_ge_35_mmol_l":false,"new_ischemic_ecg":false,"ntprobnp_ge_5000":false,"hr_arrival_ge_110":false,"troponin_mi_level":false,"urea_ge_12_mmol_l":false,"sao2_lt_90_arrival":false,"history_stroke_or_tia":false,"walk_test_hr_ge_110_or_unable":false,"intubation_respiratory_distress":false}]},"type":"http","method":"POST"},"output":{"type":"json","example":{"path":"/api/calc/ohfrs","count":2,"items":[{"score":0,"formula":"ohfrs","citation":{"id":"stiell-2013","doi":"10.1111/acem.12056","pmid":"23570474","title":"A risk scoring system to identify emergency department patients with heart failure at high risk for serious adverse events","source":"Acad Emerg Med. 2013;20(1):17-26","authors":"Stiell IG, Clement CM, Brison RJ, et al."},"max_score":15,"components":[{"factor":"history_stroke_or_tia","points":0,"present":false},{"factor":"intubation_respiratory_distress","points":0,"present":false},{"factor":"hr_arrival_ge_110","points":0,"present":false},{"factor":"sao2_lt_90_arrival","points":0,"present":false},{"factor":"walk_test_hr_ge_110_or_unable","points":0,"present":false},{"factor":"new_ischemic_ecg","points":0,"present":false},{"factor":"urea_ge_12_mmol_l","points":0,"present":false},{"factor":"co2_ge_35_mmol_l","points":0,"present":false},{"factor":"troponin_mi_level","points":0,"present":false},{"factor":"ntprobnp_ge_5000","points":0,"present":false}],"disclaimer":"Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.","formula_expression":"OHFRS = history_stroke_or_tia(1) + intubation_respiratory_distress(2) + hr_arrival_ge_110(2) + sao2_lt_90_arrival(1) + walk_test_hr_ge_110_or_unable(1) + new_ischemic_ecg(2) + urea_ge_12_mmol_l(1) + co2_ge_35_mmol_l(2) + troponin_mi_level(2) + ntprobnp_ge_5000(1); Stiell 2013 derivation; max 15; SAE risk varied from 2.8% to 89.0%; admission thresholds of total score 1, 2, or 3 had sensitivities 95.2 / 80.6 / 64.5%"},{"score":0,"formula":"ohfrs","citation":{"id":"stiell-2013","doi":"10.1111/acem.12056","pmid":"23570474","title":"A risk scoring system to identify emergency department patients with heart failure at high risk for serious adverse events","source":"Acad Emerg Med. 2013;20(1):17-26","authors":"Stiell IG, Clement CM, Brison RJ, et al."},"max_score":15,"components":[{"factor":"history_stroke_or_tia","points":0,"present":false},{"factor":"intubation_respiratory_distress","points":0,"present":false},{"factor":"hr_arrival_ge_110","points":0,"present":false},{"factor":"sao2_lt_90_arrival","points":0,"present":false},{"factor":"walk_test_hr_ge_110_or_unable","points":0,"present":false},{"factor":"new_ischemic_ecg","points":0,"present":false},{"factor":"urea_ge_12_mmol_l","points":0,"present":false},{"factor":"co2_ge_35_mmol_l","points":0,"present":false},{"factor":"troponin_mi_level","points":0,"present":false},{"factor":"ntprobnp_ge_5000","points":0,"present":false}],"disclaimer":"Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.","formula_expression":"OHFRS = history_stroke_or_tia(1) + intubation_respiratory_distress(2) + hr_arrival_ge_110(2) + sao2_lt_90_arrival(1) + walk_test_hr_ge_110_or_unable(1) + new_ischemic_ecg(2) + urea_ge_12_mmol_l(1) + co2_ge_35_mmol_l(2) + troponin_mi_level(2) + ntprobnp_ge_5000(1); Stiell 2013 derivation; max 15; SAE risk varied from 2.8% to 89.0%; admission thresholds of total score 1, 2, or 3 had sensitivities 95.2 / 80.6 / 64.5%"}]}},"iconUrl":"https://api.magentlab.com/favicon.ico"},"schema":{"type":"object","$schema":"https://json-schema.org/draft/2020-12/schema","required":["input"],"properties":{"input":{"type":"object","required":["type","method"],"properties":{"body":{"type":"object","required":["items"],"properties":{"items":{"type":"array","items":{"type":"object","required":["history_stroke_or_tia","intubation_respiratory_distress","hr_arrival_ge_110","sao2_lt_90_arrival","walk_test_hr_ge_110_or_unable","new_ischemic_ecg","urea_ge_12_mmol_l","co2_ge_35_mmol_l","troponin_mi_level","ntprobnp_ge_5000"],"properties":{"co2_ge_35_mmol_l":{"type":"boolean","description":"Serum CO2 >=35 mmol/L as assigned by the caller after applying the Stiell 2013 cutoff (2 points if true). true or false. magent does not assay CO2."},"new_ischemic_ecg":{"type":"boolean","description":"New ischemic ECG changes as assigned by the caller (Stiell 2013 derivation; 2 points if true). true or false. magent does not interpret the ECG."},"ntprobnp_ge_5000":{"type":"boolean","description":"NT-proBNP >=5000 ng/L as assigned by the caller after applying the Stiell 2013 cutoff (1 point if true). true or false. magent does not assay NT-proBNP."},"hr_arrival_ge_110":{"type":"boolean","description":"Heart rate on ED arrival >=110 as assigned by the caller after applying the Stiell 2013 cutoff (2 points if true). true or false. magent does not measure heart rate."},"troponin_mi_level":{"type":"boolean","description":"Troponin I or T elevated to MI level as assigned by the caller (Stiell 2013; 2 points if true). true or false. magent does not assay troponin."},"urea_ge_12_mmol_l":{"type":"boolean","description":"Urea >=12 mmol/L as assigned by the caller after applying the Stiell 2013 cutoff (1 point if true). true or false. magent does not assay urea."},"sao2_lt_90_arrival":{"type":"boolean","description":"Oxygen saturation <90% on ED arrival as assigned by the caller after applying the Stiell 2013 cutoff (1 point if true). true or false. magent does not measure saturation."},"history_stroke_or_tia":{"type":"boolean","description":"History of stroke or TIA as assigned by the caller (Stiell 2013; 1 point if true). true or false. magent does not take the history."},"walk_test_hr_ge_110_or_unable":{"type":"boolean","description":"Heart rate >=110 during the 3-minute walk test, or unable to perform the walk test, as assigned by the caller after ED intervention (Stiell 2013; 1 point if true). true or false. magent does not walk the patient."},"intubation_respiratory_distress":{"type":"boolean","description":"Intubation for respiratory distress as assigned by the caller (Stiell 2013; 2 points if true). true or false."}}},"maxItems":25,"minItems":1}},"additionalProperties":false},"type":{"type":"string","const":"http"},"method":{"type":"string","const":"POST"},"headers":{"type":"object","additionalProperties":{"type":"string"}}},"additionalProperties":false},"output":{"type":"object","required":["type"],"properties":{"type":{"type":"string"},"example":{"type":"object"}}}}}}},"description":"Ottawa Heart Failure Risk Scale (OHFRS; Stiell 2013 derivation). Ten caller-assigned flags (stroke/TIA 1, intubation 2, arrival HR >=110 2, arrival SaO2 <90% 1, walk-test HR >=110 or unable 1, new ischemic ECG 2, urea >=12 mmol/L 1, CO2 >=35 mmol/L 2, troponin at MI level 2, NT-proBNP >=5000 ng/L 1); integer points, max 15. Derivation SAE risk 2.8% to 89.0%. Not a medical device, not a disposition or discharge order, not EHMRG. magent does not walk the patient or read the ECG.","lastUpdated":"2026-09-28T14:47:54.478Z","serviceName":"magent","x402Version":2}]}}